| Input |
+24V dc ±10% <1A. 0V input common to HV return and chassis. |
| Control of output (output 1 only) |
0 to ±5V for 0 to 100% rated output voltage, input Z = 1M, polarity follows the control polarity. |
| Control of output (outputs 2 & 3) |
0 to +5V for 0 to 100% rated output voltage, input Z = 1M. |
| Voltage monitor (all outputs) |
Zero to +5V for zero to 100% rated output voltage, ±2% (source Z= 10k) |
| Protection (all outputs) |
All outputs are protected against intermittent arcing and continued short circuit to ground. |
| Outputs 1 & 2 only |
Output 1 voltage / polarity
(Conversion dynode output) |
Up to ±15kV / *Reversible, maximum 1kV / mS with settling to 90% of target, this can be limited to a slower speed if required (up to ±10kV is available in the smaller package size). |
Output 2 voltage / polarity
(Phosphor or EM output) |
Up to 10kV / Fixed, “N” denotes negative and “P” denotes positive (position “Y” in part number), maximum 1kV / mS with settling to 90% of target, this can be limited to a slower speed if required. |
| Output current |
5μA |
| Output ripple |
500ppm pk / pk |
| Line regulation |
<0.1% for 10% change in input voltage. |
| Load regulation |
<0.1% for 20% to maximum load. |
| Temperature coefficient |
<200 ppm / ºC |
| Drift (after 1 hour warm up) |
<0.01% per hour, <0.05 over an 8 hour period. |
| Output 3 only |
| Output voltage / polarity |
Up to 3kV / Fixed, “N” denotes negative and “P” denotes positive (position “Z” in part number) |
| Output current |
0.5mA (higher output current may be available at lower voltages, maximum power is 3W) |
| Output ripple |
<3ppm pk / pk |
| Line regulation |
<20ppm for 10% change in input voltage |
| Load regulation |
<20ppm for zero to maximum load |
| Temperature coefficient |
<50 ppm / ºC |
| Drift (after 1 hour warm up) |
<15ppm in any 15 minute period, <50ppm in any any 8 hour period |
| Current monitor (output 3 only) |
Zero to +5V for zero to 100% rated output current, ±5% (source Z= 10k) |
Mechanical Specification
|
| 2 output (max V for o/p 1 = 10kV) only types |
| Dimensions |
175.5 x 107.1 x 50 mm (7” x 2.25” x 2”) |
| Weight |
2.5Kg (5.5 lb) approximately |
| Input / control |
25way “D” connector |
| Output 1 |
Flying lead, red UL3239 un-screened 30kV cable 0.5m long. HV return to case fixings |
| Output 2 |
1 off MHV BNC connector |
| 2 or 3 output types |
| Dimensions |
216 x 203 x 86 mm (8.5” x 8” x 3.375”) |
| Weight |
3.5Kg (7.75 lb) approximately |
| Input / control |
15way “D” connector |
| Output 1 |
Flying lead, red UL3239 un-screened 30kV cable 0.5m long. HV
return to case fixings. |
| Output 2 |
2 flying leads, URM76 screened cable 0.5m long. HV return to
screen or case fixings. |