| Input: |
+24 volt dc ±10% <6A. 0V input common to HV return and chassis |
| Output, voltage / current / ripple: |
See table above. |
| Line regulation: |
<10ppm for a 1V change in input voltage. |
| Load regulation: |
<10ppm for zero to full load. |
| Drift (after 1 hour warm up): |
<100ppm per hour, <200ppm per 8 hours |
| Protection: |
Current limit to 110% (typ) auto recovery. Protected against intermittent flashover to ground |
| Control of output: |
True differential analogue input of zero to 10V dc varies output from zero to maximum
+Ve input R=100k, input range: -1V to +10V, with respect to ground
-Ve input R=100k, input range: +1V to -10V, with respect to ground |
| Output slew rate limit: |
Linear ramp 500mS / 10kV (faster rate available to special order)
|
| Polarity control: |
Negative = High (>2.5V) or open circuit. Positive = Low (<0.8V) |
| Polarity change time: |
<250mS. Between maximum rated output to maximum rated output of the opposite polarity |
| Voltage monitor: |
Zero to +10V ±2% for zero to maximum (Z= 10k) |
| Current monitor: |
Zero to +10V ±2% for zero to maximum (Z= 10k) |