OPERATING INSTRUCTIONS
1/HIGH VOLTAGES ARE DANGEROUS. ENSURE THE OUTPUT IS FULLY DISCHARGED BY SHORTING TO GROUND BEFORE TOUCHING ANY HIGH VOLTAGE CIRCUIT.
2/ During arcing, currents exceeding 1000 Amps will flow. Make connections to suit. It is important that these currents return to the high voltage power supply by the shortest possible route. The high voltage load return should be via the screen of the output cable. Failure to observe this will result in the input to the unit seeing large voltage spikes during arcing.
The unit is short circuit proof but care should be taken that the high voltage is not shorted into one of the control pin connections.

|
PIN CONNECTIONS
BERG 20W IDC header Part No 65863-069 for use with ribbon cable.
Pin 1 +24V Power supply input
Pin 2 Sync option (If fitted)
Pin 3 +24V Power supply input
Pin 4 Bias V Monitor
Pin 5 +24V Power supply input
Pin 6 Bias I Monitor
Pin 7 +24V Power supply input
Pin 8 Bias Control signal +ve Differential input
Pin 9 +24V Power supply input
Pin 10 Bias Control signal -ve Differential input
Pin 11 Signal ground
Pin 12 Detector Control signal +ve Differential input
Pin 13 Power ground
Pin 14 Detector Control signal -ve Differential input
Pin 15 Power ground
Pin 16 Detector Voltage Monitor
Pin 17 Power ground
Pin 18 Bias Polarity select i/p
Pin 19 Power ground
Pin 20 Inhibit
|
POLARITY SELECT:
|
Low = Negative
|
|
|
|
High or o/c = Positive
|
+24V signal (1mA max current)
|
|
INHIBIT:
|
Low or o/c = Off
|
|
|
(INHIBITS BOTH SUPPLIES)
|
High = On
|
+24V signal (1mA max current)
|
|
|