ZERO CROSSING REVERSIBLE HIGH VOLTAGE MODULES UP TO ±10 kV
(To ±15kV – consult the factory)

HP001Z, HP2.5Z, HP003Z, HP005Z, HP008Z, & HP010Z

Applications:

  • Bipolar Lens Supplies
  • Mass Spectrometers
  • Focus & High Voltage Bias
  • High Voltage Amplifiers

The HPZ range is a unique family of high voltage power supplies, extending the operation and versatility of Applied Kilovolts High Precision HP series. The HPZ units feature very fast slewing and settling times, together with the ability to slew cleanly through zero. With a differential control input, they operate like a high voltage amplifier with very tight temperature co-efficient of <25ppm/ºC. Note – the HPZ range also features a 4 quadrant output.


Electrical Specification

UNIT TYPE

OUTPUT

RIPPLE AT FULL LOAD

SLEWING +SETTLING TIME
-FS TO +FS

HP001ZIP025 -1kV to +1kV at 1mA 55mV peak to peak 20mSec
HP2.5ZIP025 -2.5kV to +2.5kV at 400µA 65mV peak to peak
HP003ZIP025 -3kV to +3kV at 400µA 75mV peak to peak 40mSec
HP005ZIP025 -5kV to +5kV at 400µA 170mV peak to peak 40mSec
HP008ZIP025 -8kV to +8kV at 400µA 300mV peak to peak
HP010ZIP025 -10kV to +10kV at 400µA 300mV peak to peak 50mSec

INPUT VOLTAGE:

+24 V ±10% at 1 A

OUTPUT VOLTAGE:

See table above.

CONTROL VOLTAGE:

-10V to +10V give -max. kV to +max. kV (e.g. -2.5kV to +2.5kV). NB: Internal manual potentiometer control not fitted.
VOLTAGE MONITOR: -10V to +10V for -max. kV to +max. kV ±2% o/p impedance 10kohms

LOAD REGULATION:

Less than 100 ppm for zero to max. load.
LINE REGULATION: Less than 20 ppm for 1V change in I/P volts.

I MONITOR:

-10 to +10V represents -100% to +100%

TEMPERATURE COEFFICIENT:

25 ppm per °C.

OPERATING TEMPERATURE:

0°C to +45 °C.

Mechanical Specification

SIZE:

159 x 184.5 x 47 mm. NB. Grounding of the case is via fixing bolts.

OUTPUT CABLE:

URM43 length 0.5 meter.
INPUT CONNECTOR: BERG 20 Way IDC header.

PDF Downloads

Data Sheet | Installation Notes | Outline Drawing
Home | Company Profile | M/S Applications | Contact Us | Representatives