| Input: |
+24 volt dc ±10% <3A. 0V input common to HV return and chassis. |
| Output, voltage / current / ripple. |
See table above. |
| Line regulation: |
<10ppm for a 1V change in input voltage. |
| Load regulation: |
<10ppm for zero to full load. |
| Drift (after 1 hour warm up) |
100ppm per hour, 200ppm per 8 hours |
| Protection |
Current limit to 110% (typ) auto recovery. Protected against intermittent flashover to ground |
| Control of output |
True differential analogue input of zero to 10V dc varies output from zero to maximum
+Ve input R=100k, input range: -1V to +10V, with respect to ground
-Ve input R=100k, input range: +1V to -10V, with respect to ground |
| Polarity control |
Negative = High (>2.5V) or open circuit. Positive = Low (<0.8V)
|
| Polarity change time |
<250mS. Between maximum rated output to maximum rated output of the opposite polarity into 200pF |
| Voltage monitor |
Zero to +10V ±2% for zero to maximum (Z= 10k) |
| Current monitor |
Zero to +10V ±2% for zero to maximum (Z= 10k) |
| Polarity monitor 1 |
High = positive output (24V via 2k2). Low = negative output (0V via 1k5) |
| Polarity monitor 2 |
High = negative output. Low = positive output |