100W HW Series Data Sheet

  • 1kV, 2.5kV, 5kV, 10kV, 20kV, 30kV, 40kV & 50kV
  • High frequency switch mode control
  • Internal control or externally programmable
  • Short circuit and flashover proof
  • 24 hour burn in
  • Safety assessed to EN61010-1

Applications

  • Lasers
  • Capacitor charging
  • Ion Pumps
  • X-Ray
  • Ion Implantation
  • Magnetrons

The HW series of high voltage modules covers the range from 1kV to 50kV giving 100Watts of output power. Control of the output voltage is by internal potentiometer or by external potentiometer or by an external 10 volt analogue control voltage. Pins 1 to 10 of the 12 pin Molex input connector are pin compatible with both the high precision HP series and the general purpose KS series.

All units are short circuit proof and use high frequency switching techniques, in conjunction with a ferrite step-up transformer to control the output. The units operate from a 24V input and have an efficiency of around 80%.

O/P Current Control is now available as Constant Current Option
Pin Connection & Safety Instructions | 200W HX Series Data Sheet

Electrical Specification

UNIT TYPE

POLARITY

OUTPUT

RIPPLE AT FULL LOAD

  HW001P POSITIVE 50 volts to 1kV at 100mA <0.1% peak to peak
   HW001N NEGATIVE
 HW2.5P POSITIVE 100 volts to 2.5kV at 40mA <0.1% peak to peak
 HW2.5N NEGATIVE
HW005P POSITIVE 250 volts to 5kV at 20mA <0.1% peak to peak
HW005N NEGATIVE
HW010P POSITIVE 500 volts to 10kV at 10mA <0.1% peak to peak
HW010N NEGATIVE
  HW020P POSITIVE 1.5kV to 20kV at 5mA <0.1% peak to peak
 HW020N NEGATIVE
  HW030P POSITIVE 1.5kV to 30kV at 3mA
<0.1% peak to peak
 HW030N NEGATIVE
 HW040P POSITIVE 2kV to 40kV at 2.5mA <0.5% peak to peak
(measured with 200pf load capacitance)
 HW040N NEGATIVE
  HW050P POSITIVE 3kV to 50kV at 2mA
  HW050N NEGATIVE

INPUT VOLTAGE: +24 volt d.c. ± 10% at 6A. Negative input terminal common to HV earth return
OUTPUT VOLTAGE: See separate table
LINE REGULATION: Less than 0.1% for input changes of 1 volt
LOAD REGULATION: Less than 0.1% for load changes from 10% to maximum. (Measured at maximum voltage)
OVERLOAD PROTECTION: Flashover and short circuit proof. Trip on over current, reset by on/off
TEMPERATURE COEFFICIENT: 300ppm/ °C or better. (Consult factory for temperature coefficients)
CONTROL:
  • INTERNAL potentiometer
  • EXTERNAL potentiometer
  • 10V analogue signal. (0 to +10V gives zero to maximum output, tolerance ±2%). Input impedance nominally 200Kohm.
READOUT: Voltage monitor 0 to +10V represents zero to maximum output, tolerance ±3% (source resistance 10 kohm)
Current monitor (option) 0 to +10V ±7% represents zero to maximum current (source resistance 10 kohm)
NB. Current monitor (supplied as standard) includes the internal feedback current of about 100uA. Precision I monitor (available as an option) removes this current to give a true reading of load current.
OPERATING TEMPERATURE: 0 °C to +45 °C
STORAGE TEMPERATURE: -35°C to +85°C
R.F.I.: Choke input filter.  Steel case for low radiated magnetic field.
SAFETY: Complies with EN61010 Part1.

Mechanical Specification

SIZE:

All units 230 x 135 x 60mm
(except HW040 & HW050 size 280 x 135 x 60mm)

WEIGHT:

1.5kg
OUTPUT: By 0.5 metre of screened cable (1 metre on HW030, HW040 & HW050). N.B. Reducing the cable length may increase the ripple voltage.
INPUT CONNECTOR: Molex 12 pin (mating connector supplied)
ORDER CODE:
Series Code HW
o/p Voltage Polarity Options Code Temp Co
001=1kV P= +ve IS = I Mon 300 = <300ppm/°C
2.5=2.5kV N= -ve P = Precision Monitor
005=5kV CS = Constant Current
010=10kV o/p Control
015=15kV +Imon
020=20kV CP = Constant Current
030=30kV o/p Control
040=40kV +Precision Imonitor
050=50kV

eg. 100W 20kV Negative unit with Precision Current Monitor : HW020NIP300

Current Monitor on HW Units

There are two current monitor options available for the HW series.
Stack Return Current Monitor
Simple lower cost Current Monitor: Current is measured between pin 11 and pin 9 (0 volt)

The current measured includes internal feedback currents used to control the unit. These currents, which are proportional to the output voltage, are 100uA on the HW series.

Load current Measured current I monitor current
0 mA
100 uA
HW series at full voltage
0 mA
50 uA
HW series at half voltage
1 mA 1.1 mA
HW series at full voltage
2 mA
2.05 mA
HW series at half voltage

Precision Current Monitor
The current monitor output is 0 to +10V represents 0 to true maximum current.
O/p impedance = 10kohms

PDF Downloads

Data Sheet | Installation Notes | Installation Notes Constant Current Option | HW001 to HW030 Outline Drawings